Based on the temperature and humidity control technology cultivated over many years as an environmental tester ETAC, the LABONIC series is equipped with easy-to-use and simple functions suitable for stability tests. This is a drug stability test monitoring system that centralizes control and monitoring of temperature, humidity, illumination, and intensity of stability tests on a single PC, greatly reducing the daily workload of researchers. By combining these systems, ETAC provides total support for R&D activities centered on new drug development.

Basic performance

  • Temperature range:+20 to +45°C
  • Humidity range60-80%RH
  • capacity330L (LX330), 800L (LX800)
  • Inside dimensions600 x 1000 x 550 (LX330), 1000 x 1000 x 800 (LX880)
  • power (button on TV, etc.)AC100V / AC200V (depending on model)
Product Catalogs and Specifications (PDF)
specification sheet

Product Features

  • Covers the temperature and humidity control range required for typical test conditions in stability testing
  • Non-frost design for continuous operation without interruption of testing
  • Capacitive polymer humidity sensor as standard equipment, eliminating the need for periodic wick replacement
  • Uses refrigerant (HFC) that meets CFC regulations
  • Simplifies testing by using the direct water supply method as standard.
  • Unique circulation system improves temperature and humidity distribution performance and increases test space volume
  • Up to 18 sliding sample shelves (50mm pitch) can be installed
  • AC100V power supply design that can be installed anywhere

operability

Pharmaceutical Stability Test Monitoring System

This monitoring system allows centralized management of up to 64 test instruments using a single PC. The system can manage temperature, humidity, illuminance, and intensity based on validation, eliminating the need for recorders and other management tools and making it possible to go paperless.

  • Centralized Management MonitorCentralized management of up to 64 units from a single PC. Record, graph, and report temperature, humidity, and illumination (optional).
  • Paperless OperationAutomatic recording and electronic data management for increased efficiency and audit compliance.
  • Sample ManagementSample management, sample count management, and notification functions
  • securityLogin ID/password settings for each person in charge, operation history records, data tampering prevention, and access restrictions

specification sheet

model (e.g. of a vehicle)

LX330

LX800

DH18

DH30

External dimensions (W x H x D mm)

860 x 1825 x 725

1260 x 1825 x 975

4425 x 2405 x 2000

4425 x 2405 x 2700

Internal dimensions (W x H x D mm)

600×1000×550

1000×1000×800

3310 x 2200 x 1870

3310 x 2200 x 2570

Temperature range:

+20°C to +45°C

Humidity range

60% RH to 80% RH

Temperature/Humidity Variation Range

±0.5°C/±2.0%RH

±0.3°C/±2.5%RH

Temperature and humidity distribution

±1.0°C/±5.0%RH

controller

PID-controlled temperature and humidity controller

sensor

Temperature PT100Ω Humidity Capacitive polymer sensor

Ambient operating temperature

+5°C to +30°C

Weight (kg)

Approximately 170

Approx. 240

Exterior Material

Bonded steel sheet, baked, painted finish

Acrylic resin steel plate

Interior Material

Stainless steel plate

refrigerator

Air-cooled, totally enclosed refrigerator (HFC134a)

Air-cooled, totally enclosed refrigerator (HFC404a)

Door opening dimensions

Single door W850×H1820

Floor load capacity

600kg/㎡ (surface load)

power (button on TV, etc.)

AC100V1φ50/60Hz Voltage fluctuation range within ±10

AC200V3φ50/60Hz Voltage fluctuation range within ±10

Maximum load current

14A

24A

39A

ground (elec)

Class D grounding

humidified water

Pure water (conductivity less than 10 μ/cm) Pressure 0.06 MPa to 0.3 MPa

Pure water (conductivity less than 10 μ/cm) Pressure 0.1 MPa to 0.3 MPa

drainage

Natural drainage (open-air connection)

security device

Earth leakage circuit breaker, over-temperature protector, ramming preventer, independent over-temperature protector, blower overheat protection, refrigerator overload disconnect device, heating heater overload protection fuse, humidifier overload protection fuse, automatic power failure recovery

Earth leakage circuit breaker, lighting light circuit earth leakage circuit breaker, test room overtemperature protector, heating heater overtemperature protector, ramming heater protector, blower overheat protector, refrigerator overload disconnect device, high/low pressure switch, heating heater overload protective breaker, control circuit protective breaker, lighting and thermal heater circuit protective breaker, automatic power failure recovery

standard equipment

Power cable 2 m, Φ50 measuring hole, caster with adjuster, 20 cm drain hose, trough output terminal, direct humidified water supply mechanism

Observation window (350 x 350 mm), room lighting (fluorescent lamp), Φ54 measurement hole, ventilation fan, refrigerator pressure gauge, humidified water pressure gauge, humidified water strainer, room emergency stop switch, direct humidified water supply mechanism

accessory

2 shelves, glass tube fuse, instruction manual, warranty card

User’s Manual, Warranty Card

Performance is based on an ambient temperature of +23°C and no sample. (LX series according to JTMK01, DH series according to JTMK03)

Option (LX series)
  • Temperature/Humidity recorder (100 mm chart, strike-point type)
  • Shelf (with support bracket, up to 15 kg)
  • Load-bearing shelves (with support brackets, up to 30 kg)
  • Double-opening door specification (LX800) *Shelves are dedicated because a pillar is installed in the center of the inner tank.
  • Water supply tank (ceiling-mounted type)*The height and depth of the external dimensions will change.
  • Measuring hole φ50
  • Ion-exchange water purifier unit
  • Temperature/humidity output terminal 0-4V DC
  • Service ponel limit switch
  • Floor Fixture
Option (LX series)
  • Temperature/Humidity recorder (100 mm chart, strike-point type)
  • Double swinging door (W1400 x H1820mm)
  • Floor reinforcement plate (to prevent denting due to point loads)
  • Measuring hole φ54
  • Ion-exchange water purifier unit
  • Temperature/humidity output terminal 0-4V DC
  • Service ponel limit switch