Environmental Testing ChamberTemperature Cycling Chamber

WINTECH NEO

WINTECH NEO is a high-performance temperature cycle tester based on ETAC's proprietary technology. It uses the low-GWP refrigerant R-448A (GWP value 1387), which reduces environmental impact by approximately 65% compared to conventional R-404A. The space-saving design and energy-saving features combine to provide a sustainable testing environment. Furthermore, it has excellent temperature recovery performance in a short period of time, significantly shortening the test time.

Basic performance

  • Refrigeration equipment: air-cooled and water-cooled types are lined up.
  • Internal dimensions (W x H x D mm): 370 x 330 x 400, 370 x 500 x 400, 650 x 500 x 400, 700 x 500 x 600
  • Contents: 48L, 74L, 130L, 210L
  • Low temperature test temperature range: -65°C to 0°C (-80°C to 0°C for water-cooled type)
  • High temperature test temperature range: +60°C to +200°C
  • Pre-cooling temperature range: -75°C to 0°C (-80°C to 0°C for some water-cooled types)
  • Preheating temperature range: +60°C to +225°C

operability

Large LED and color LCD touch panel

Large LEDs on the top of the ETACOM allow operation and abnormal conditions to be checked at a glance, and the 7.5-inch wide color LCD touch panel provides intuitive and easy-to-understand operability.

Automatic storage of test chamber temperature

Automatically saves test room temperatures even when not in operation. The history can be checked and downloaded on a monitor or USB memory stick.

Various display functions

Graphical display of program progress and test conditions facilitates confirmation.

Configuration functions that support high performance

Temperature, exposure time, and number of cycles can be easily entered and edited. Elapsed cycles can be managed individually with a counter with reset.

Maintenance Management Functions

Sensors placed around the chiller constantly monitor the operational status. In the event of trouble, the operating conditions are instantly saved, enabling quick identification of the cause.

Optional additional features

Flexible test operation is supported by functions such as the ability to change exposure time and the ability to interrupt specified cycles.

Main functions (list)

  • Number of program memory: Max. 30 types (No.1 to No.30)
  • Upper and lower limit temperature alarm function
  • weight function
  • Auto start function (operation/standby)
  • End time display (calendar display of year, month, date, hour and minute)
  • Test room temperature data download function
  • maintenance management monitoring function
  • High/low temperature soaking time: up to 120 min.
  • Room temperature soaking time: up to 99 minutes
  • Alarm history storage function
  • Troubleshooting display screen
  • Time signal output (250 VAC 3A/3 channels)
  • Interlock contact (AC220V 10A)
  • Test end output (AC250V 3A)
  • External alarm output (AC250V 3A)
  • Communication function (RS485: optional)

Environmentally Friendly

Low GWP refrigerant R-448A adopted

The use of refrigerant R-448A (GWP value 1387) reduces environmental impact by approximately 65% compared to conventional R-404A. It also meets the 2025 target value (1,500 or less) under the Fluorocarbons Emission Control Law, and is environmentally friendly and safe.


air-tank temperature cycle tester

WINTECH NEO (300°C specification)

The WINTECH series with 300°C specifications is now available for reliability evaluation of power devices for automotive and other industrial applications with high voltage and high current. The WINTECH series has improved heat resistance and insulation performance during high-temperature operation, achieving both basic performance and safety at a high level.

Basic performance

  • Chiller: air-cooled (NT3702A), water-cooled (NT3702W)
  • Internal dimensions (W x H x D mm): 370 x 450 x 400
  • Contents: 66L
  • Low temperature test temperature range: -65°C to -10°C
  • High temperature test temperature range: +80°C to +300°C
  • Pre-cooling temperature range: -75°C to -20°C
  • Preheating temperature range: +90°C to +350°C
  • Packing for high temperature damper

Low-temperature recovery time shortening function

When shifting from "high temperature rinsing" to "low temperature rinsing" during a 2-zone test, outside air is introduced until the set temperature is reached, significantly shortening the recovery time. This is particularly effective in accelerating the time required for specimens to return to temperature under conditions with a large temperature range or under load.

Safety Considerations

Insulation is applied to areas that are easily touched by human hands, such as cable measurement holes that are prone to high temperatures, to ensure safety even if accidentally touched. Safety is ensured down to the smallest detail.


Liquid bath thermal shock tester

WINTECH NEO LIQUID Series

This liquid bath type thermal shock tester is effective in reducing test time for evaluation of mounted products. This tester is best suited for evaluating the reliability of connections of mounted automotive electronics products, and its testing method is designed to meet the needs for shortening the time required for the development of new vehicles. The inside of the chamber and the specimen transfer space are welded together to ensure a high level of confidentiality. Furthermore, a vapor recovery device is provided as standard equipment to significantly reduce the consumption of brine solution.

Air cylinder method

To protect the specimens during the test, an air cylinder system is used to drive the specimen basket. The specimens are safely protected even in the event of power failure or malfunction, and the door cannot be opened or closed during the test to ensure safety.

increased load-bearing capacity

Sample baskets are available in 3 kg (LT20, 60) and 6 kg (LT80) load capacities, and a larger basket for A4-size samples is also available for a variety of sample evaluations.

Brine solution automatic feeder

An automatic brine supply function is provided as standard equipment to enhance test stability. Both low and high temperature tanks maintain the liquid level and automatically prepare for the next test.

Removable sample basket

A removable sample basket is used to improve workability. Samples can be smoothly replaced.

Brine solution cleaning system (optional)

Brine solution is kept clean even during long-term tests or tests with frequent sample changes. Built-in cleaning system for quick and easy cleaning.

System Upgrade (optional)

System linkage between thermal shock testing and continuity reliability evaluation tester (MLR22) is possible. Connection reliability testing can be performed efficiently.


option

It can be customized with a variety of options that improve functionality and ease of use.

Sample temperature control

Even if the material or mass of the sample changes, the exposure time can be accurately controlled.

paperless recorder

Data can be saved on an SD card and imported to a PC using dedicated software.

RS485 interface

Remote operation and data management are possible through connection to a PC.

Rectangular Cable Hole

One or two additional locations can be added on both sides.

Power Quantity Monitor

The amount of power consumption and CO2 emissions of the testing equipment can be managed.

Air compressors

Built-in dedicated box to drive damper and door opening/closing mechanism.

Round measurement hole

Equipped with one location on the left side as standard, additional locations can be added.

Sample baskets and receptacles

Mesh sample baskets and receiving fittings are available.

Downwind Sensor

Additional sensors for a wide range of testing conditions.

Cycle counter (with separate instrument)

An additive counter that can retain the number of cycles even when the power is turned off.

AC100V outlet

Can be used as a power supply for measuring instruments (rated 3A).

Function to change exposure time

It is possible to change the exposure time during the test.

Designated cycle interruption function

The test can be automatically interrupted at each set cycle and resumed as needed.

specification sheet

Temperature Cycling Tester (Gas Tank Type)

WINTECH NEO AIR

model (e.g. of a vehicle)

NT551A

NT1051A

NT1251A

NT1051W

NT1251W

NT2051W

NT3702A

NT3702W

Temperature cycle method

Cold/heat air switching system with damper (sample stationary system)

Applicable Tests

2-zone and 3-zone temperature cycling tests

Low temperature test temperature range

-65°C to 0°C

High temperature test temperature range

+60°C to +200°C

+80°C to +300°C

Return Time to Temperature

Within 5 minutes

Within 4 minutes

Within 10 minutes

(SR function ON)

Within 7 minutes

(SR function ON)

Low temperature/time

-40°C/30 min.

-55°C/30 min.

-65°C/30 min.

-40°C/30 min.

Room temperature soaking time

5 min.

0 minutes

High temperature exposure temperature / time

125°C/30 min

150°C/30 min

250°C/30 min

300°C/30 min

sample

Plastic mold IC 2.5 kg + feed basket, receiving fixture 1 kg

Plastic mold IC 2.5 kg + feed basket, receiving fixture 2 kg

Plastic mold IC 2.5kg + feed basket, receiving fixture 2.8kg

Plastic mold IC 2.5 kg + sample basket, receiving fixture 1 kg

Plastic mold IC 5kg + sample basket, receiving bracket 2kg

Plastic mold IC 5kg + sample basket, receiving fixture 2.8kg

Aluminum piece 1.25kg

Aluminum strip 2.5kg

Control sensor position

upwind

Pre-cooling temperature range

-75°C to 0°C

₋80°C to 0°C

-75°C to -20°C

Preheating temperature range

+60°C to +225°C

+90°C to +350°C

Guaranteed ambient temperature

23°C±5°C

Ambient operating temperature

+10°C to +35°C

+10°C to +32°C

+5°C to +35°C

+10°C to +35°C

+5°C to +35°C

Tank Structure

Three-tank type (test chamber, high-temperature chamber, low-temperature chamber)

Test chamber dimensions (W x H x D mm)

370 x 330 x 400

370 x 500 x 400

650 x 500 x 400

370 x 500 x 400

650 x 500 x 400

700 x 500 x 600

370×450×400

External dimensions (W x H x D mm)

Not including protrusions

1150 x 1800 x 1325

1150 x 1940 x 1770

1430 x 1940 x 1720

1150 x 1940 x 1620

1430 x 1940 x 1470

1480 x 1940 x 1670

1150 x 1980 x 1720

1150×1980×1570

Main unit weight (kg)

Approx. 730

Approx. 1050

approximately 1230

Approx. 1020

Approx. 1180

Approx. 1280

Approx. 1150

Approx. 1000

Test chamber load capacity (kg)

30 (Equal distribution load)

30 (Equal distribution load)

100 (Equal distribution load)

30 (Equal distribution load)

100 (Equal distribution load)

100 (Equal distribution load)

30 (Equal distribution load)

30 (Equal distribution load)

Allowable number of sample baskets

six flat objects (e.g. tickets, pieces of cloth, pieces of cloth, etc.)

seven (used in legal documents)

six flat objects (e.g. tickets, pieces of cloth, pieces of cloth, etc.)

Allowable load of material basket

5.0kg/sheet

7.5kg/sheet

5.0kg/sheet

door opener

single swing door

measurement hole

φ50mm round measurement hole

(1 pcs. on the left side of the main unit)

30mm x 100mm square measurement hole

(1 pcs. on the left side of the main unit)

Control method

PID control method (upwind)

PID control method

power-saving method

ECO operation (pre-cooling/pre-heating suspension method with learning function)

Setting method

LCD touch panel system

Display method

7.5″ color LCD display

Display resolution

1°C

Number of program registrations

Up to 30 types

(Program No. 1 to No. 30)

Temperature Cycle

Max. 9999 cycles

Exposure time setting

High/low temperature rinsing max. 120 min|Rinsing at room temperature max. 99 min

memory capacity

16GB

interface

USB2.0 TYPE-A connector

Ancillary Functions

Auto start (operation, standby), automatic defrosting, wait, self-monitoring monitor, test end time display, elapsed cycle display, trouble handling display, automatic pre-cooling and preheating temperature setting, alarm history storage, test end status selection (cycle stop, stop after defrost, continue test preparation after cycle end), cycle with reset counter (4 conditions), end-of-test output, time signal output (3 points), upper and lower limit temperature alarm function, trouble message display, graphic display, USB port, pause, cold chamber drying function, etc.

Auto start (operation, standby), automatic defrosting, wait, self-monitoring monitor, test end time display, elapsed cycle display, trouble handling display, automatic pre-cooling and preheating temperature setting, alarm history storage, test end status selection (cycle stop, stop after defrost, continue test preparation after cycle end), cycle with reset Counter (4 conditions), end-of-test output, time signal output (3 points), upper and lower limit temperature alarm function, trouble message display, graphic display, USB port, pause, SR function, cold room drying function, etc.

Upwind and downwind temperature sensors

Pt100

(JIS C1604)

Temperature sensor

Pt100

(JIS C1604)

Refrigeration method

dual refrigeration system

refrigerator

Air-cooled sealed reciprocating compressors

Air-cooled Hermetic Scroll Compressors

Scroll type compressor

refrigerant

R-448A+HFC23

R-404A+R-23

heater

Strip Wire Heaters

ventilator

sirocco fan

Damper drive unit

air cylinder

safeguard

Earth leakage circuit breaker, blower thermal relay, power supply reverse phase prevention relay, high temperature room temperature overload preventer, test room temperature overload preventer, low temperature room temperature overload preventer, test room temperature upper/lower limit alarm device, refrigerator 1 and refrigerator 3 overload relay, refrigerator 1 and refrigerator 3 high/low pressure switch, proximity switch for damper, door open detection mechanism Sensor disconnection detection function, ambient temperature abnormality detection function, external alarm output, interlock terminal
Earth leakage circuit breaker, blower thermal relay, power supply reverse phase prevention relay, high temperature room temperature overload preventer, test room temperature overload preventer, low temperature room temperature overload preventer, test room temperature upper/lower limit alarm device, refrigerator 1 and refrigerator 3 overload relay, refrigerator 1 and refrigerator 3 high/low pressure switch, proximity switch for damper, door open detection mechanism Sensor disconnection detection function, cooling water temperature abnormality detection function, cooling water breakage detection function, external alarm output, interlock terminal

Earth leakage circuit breaker, blower thermal relay, blower reversal prevention relay, high temperature chamber temperature overload preventer, test chamber temperature overload preventer, low temperature chamber temperature overload preventer, test chamber temperature upper/lower limit alarm device, refrigerator 1 and refrigerator 3 overload relay, refrigerator 1 and refrigerator 3 high/low pressure switch, proximity switch for damper, door lock mechanism, sensor disconnection detection function, ambient temperature abnormality detection function, external alarm output, interlock terminal

power (button on TV, etc.)

AC200V 3 phase 50/60Hz Power supply fluctuation ±10

Maximum power consumption (kVA)

19

30

32

35

44

48

35

40

Maximum load current (A)

55

87

93

100

125

138

101

113

Operating current (A)

26

49

50

56

63

65

71

80

Refrigeration machine exhaust heat (kW)

7

11

11

Cooling water volume (liter/min)

38 (water temperature 25°C)/55 (water temperature 32°C) connection bore 1’1/4B

47 (water temperature 25°C)/82 (water temperature 32°C) connection bore 1’1/4B

Coolant inlet pressure (MPa)

0.2 to 0.5

circulating volume

55 liter/min (water temperature 32°C)

Water supply water pressure

0.2 to 0.5 MPa

air

0.4 to 0.7MPa (dry air) connected to the back of the main unit with a φ6mm (outer diameter) air hose

drainage

(e.g., drainage during defrosting)

Atmospheric release (1 location) φ8mm (I.D.) x φ11mm silicone hose

accessory

Silicone stopper for measurement hole (2 pcs), instruction manual (1 copy), warranty card (1 copy), inspection certificate (1 copy)

Silicone plugs for measuring holes (2), Y strainer for cooling piping (1), instruction manual (1 copy), warranty card (1 copy), inspection certificate (1 copy)

Silicone plug for measurement hole (1 pc), heat-resistant plug for measurement hole (1 pc), instruction manual (1 copy), warranty card (1 copy), inspection certificate (1 copy)

Thermal shock tester (liquid tank type)

WINTECH NEO LIQUID

model (e.g. of a vehicle)

LT20W

LT60W

LT80W

system

Sample basket moving type (2- or 3-zone switchable)

Low temperature test temperature range

-65°C to 0°C

High temperature test temperature range

+50 to +200°C

Temperature fluctuation range

±0.5°C

Pre-cooling temperature range

MAX -70°C

Pre-cooling temperature fall time

Within 60 minutes

+20°C to -65°C

Within 90 minutes

+20°C to -65°C

Preheating temperature range

MAX +200°C

Preheat temperature rise time

Within 60 minutes

From +20°C to +150°C

Within 90 minutes

+20°C to -150°C

Ambient operating temperature

+5°C to +40°C

Sample

Plastic Mold IC 0.5kg

Printed circuit board 1.5kg

Printed circuit board 2.0kg

Temperature (low-temp/high-temp tank)

Low temperature tank -65°C|High temperature tank +150°C

exposure time

5 min.

Return Time to Temperature

2 minutes

3 minutes

Temperature measurement position

Near the sample basket

Tank Structure

3-tank type (low temperature, high temperature, room temperature)

Sample basket dimensions (W x H x D mm)

120 x 120 x 150

170 x 170 x 250

220 x 220 x 310

External dimensions ((W x H x D mm))

1480 x 1880 x 1300

1740 x 1880 x 1500

1810 x 1850 x 1500

Main unit weight (kg) (excluding brine solution)

Approx. 1000

approximately 1500

Approximately 1700

Fluorine inert liquid volume (high/low temperature side)

High temperature side Approx. 33 liters

Low temperature side Approx. 42 liters

High temperature side Approx. 48 liters

Low temperature side Approx. 62 liters

High temperature side Approx. 55 liters

Low temperature side Approx. 75 liters

Allowable load of sample basket (kg)

2

6

Control method

PID control method

Setting method

LCD touch panel interaction

Display method

LCD graphic display

Display resolution

0.1°C

Temperature cycle setting

MAX 9999 cycles

Ancillary Functions

Operation reservation function, zone selection function, operation start selection function, de-icing operation function, end state selection function, manual operation function, total time meter

Temperature sensor

Pt100

(JIS C1604)

Refrigeration method

Low-temperature tank Fully-enclosed, water-cooled, dual-refrigeration system

Recovery unit Totally enclosed water-cooled single-stage refrigeration system

Low-temperature tank Scroll-type water-cooled dual-refrigeration system

Recovery unit Totally enclosed water-cooled single-stage refrigeration system

refrigerant

Low temperature tank R-404A and R-23

Recovery unit R-404A

heater

sheathed heater

(SUS316L)

ventilator

Propeller Type Agitator

Damper drive unit

Air cylinders (2 vertical, 1 horizontal)

Air cylinders (4 vertical, 1 horizontal)

Brine Liquid Management System

Built-in vapor recovery device and automatic liquid feeder

safeguard

Leakage circuit breaker, agitator current error, hot tank temperature error, cold tank temperature error, refrigerator 1 error, refrigerator 2 error, refrigerator for recovery unit error, air pressure error, liquid shortage, drive unit error, cooling water error, emergency stop switch

power (button on TV, etc.)

AC200V 3-phase 50/60Hz Voltage fluctuation tolerance ±10% or less Noise level 3kV or less, noise period 1μsec or more, frequency fluctuation tolerance ±5% or less

Maximum power consumption (kVA)

10

16

18

Rated current (A)

43

47

54

Primary-side electrical work

AC200V 3-phase 50/60Hz Voltage fluctuation tolerance ±10% or less Noise level 3kV or less, noise period 1μsec or more, frequency fluctuation tolerance ±5% or less

Primary air construction

0.4 to 0.7 MPa (dry air) External φ6mm hose connection

coolant

Water volume 55 liter/min (water temperature 25℃) Bore diameter 20A

Water volume 70 liter/min(water temperature 25℃)

Bore 25A

Water volume 100 liter/min (water temperature 25℃) Bore 32A

drainage

Waste water condensed in refrigerator: 15A Separated waste water from recovered liquid: 15A Atmospheric release

Standard accessories

Stainless steel (SUS304) sample basket (with temperature sensor T thermocouple), hose for drainage, hose for draining liquid, caster, instruction manual, warranty card, inspection certificate