
Product & Service Guide
General catalog of ETAC's products and services. It provides a comprehensive overview of our entire business, including introduction of our environmental testing equipment and other products, contract testing for automotive and electronic components, and inspection and calibration services.

Reliability Test & Analysis Contracted Services
This is a guide to our reliability testing and analysis contract services. We provide environmental testing, life testing, and failure analysis for automotive and electronic components in compliance with international standards to improve brand value and ensure safety.

HIFLEX NEO-E Product Catalog
Product catalog for HIFLEX NEO-E series low-temperature constant-temperature/humidity chamber. We introduce new functions, comfortable operability with high reliability, and unique mechanisms reflecting opinions from testing sites.

HIFLEX NEO-E Product Specifications
This is the product specification table for the HIFLEX NEO-E low-temperature constant-temperature humidifier, which lists the temperature range, size, refrigerant, and other specifications for both the FX and FL types.

HIFLEX NEO-ES Product Catalog
Product catalog for HIFLEX NEO-ES series compact/multi-stack low-temperature/hygrothermal hygrostats. We introduce features ranging from overwhelmingly space-saving design to high performance and unique refrigeration circuits.

HIFLEX NEO-ES Product Specifications
Specifications for HIFLEX NEO-ES are shown in the table below.

HIFLEX SC Product Catalog
Product catalog for HIFLEX SC low-temperature constant-temperature/humidity chamber. We introduce various functions and stable performance that support various testing scenes, while the simple structure provides easy handling.

HIFLEX SC Product Specifications
Specifications for HIFLEX SC low-temperature/hygrothermal hygrostats, including temperature and humidity ranges, sizes, refrigerants, and other basic performance information for both FX and FL types.

HIFLEX SBC Product Catalog and Specifications
This is the product catalog and product specification table for HIFLEX SBC, a safety-increasing constant-temperature chamber for rechargeable battery evaluation. Product features that support the testing environment such as space-saving design, fail-safe function, and large measurement holes are introduced here.

WINTECH NEO Product Catalog
Product catalog for the WINTECH NEO series of temperature cycle testers, introducing the features and lineup of the entire series, including the 300°C special version and the liquid bath type thermal shock tester WINTECH LT.

WINTECH NEO Product Specifications
This is a specification table for the WINTECH NEO Series of temperature cycle testers. It covers information on the basic performance of the equipment such as temperature range and temperature rise time for air-cooled, liquid-cooled, and 300°C specifications.

HISPEC Product Catalog
Product catalog for HISPEC series high temperature constant humidity chamber. We introduce a wide variety of product lineup for various situations from temperature testing to heat treatment and drying in production lines.

COLONIA Product Catalog/Specifications
This is a product catalog for the COLONIA series of large constant-temperature (constant-humidity) chambers. We introduce a wide variety of features including easy-to-read room display panels, extended effective space, and a wide range of options.

LABONIC Product Catalog/Specifications
This is a product catalog and usage chart for LABONIC, a pharmaceutical stability tester/stability laboratory. Long-term continuous operation and maintenance-free operation are realized with non-frost design and high-precision sensors.

ShockEvent Product Catalog
ShockEvent product catalog. Cold and thermal shock testers conforming to international standards, with a wide temperature range and low GWP refrigerant, providing stable and reliable testing while reducing environmental impact.

ShockEvent Product Specification Table
This is a specification sheet for the WeissTechnik ShockEvent. It covers detailed information on the various basic capabilities of the device, including temperature range, refrigerant, test conditions, humidity control, operating interface, and power specifications.

ClimeEvent Product Catalog
This is the product catalog for ClimeEvent. ClimeEvent not only meets a wide range of the world's major test standards and achieves the industry's fastest temperature change of 25°C/min, but also uses low-GWP refrigerants.

ClimeEvent Product Specification Table
This is a specification sheet for the WeissTechnik ClimeEvent. It covers detailed information on the various basic capabilities of the device, including temperature range, refrigerant, test conditions, humidity control, operating interface, and power specifications.

ESS-J Product Catalog
Product catalog for ESS-J. Designed for the Japanese market, this rapid temperature change tester meets the world's major test standards and achieves the industry's highest level of reliability. It also uses the new refrigerant R-469A.

SIR13 Product Catalog
This is the product catalog for SIR13 insulation reliability measurement system. It introduces model lineups, types of SMU boards developed independently, and electrochemical migration measurement methods.

ED71 Technical Data
ED71 technical data. This system is specialized for instantaneous breakdown detection and provides highly accurate detection in 1 µsec increments. It can also provide superior analysis performance compared to other measurement systems.

HIFLEX When temperature and humidity do not drop
If the temperature and humidity do not drop, a frost condition may be present in the cooler. This section explains how to check for frost and how to effectively defrost (defrost).

WINTECH NEO When the temperature in the low-temperature chamber does not drop
When the temperature in the cold room does not drop, the main cause may be frost or low refrigeration capacity. This section describes specific remedies such as manual defrosting and adjusting defrost intervals.

WINTECH NEO When cycle operation does not start
Possible causes of "when cycle operation does not start" include insufficient temperature setting, test interruption condition, door opening/closing, and activation of the chiller protection circuit. The following is an explanation of how to deal with each of these.

When HISPEC error/trouble cannot be reset
The following section describes how to safely restart the equipment by implementing error procedures after the buzzer stops, the power is turned off, and the RCD operation is completed, to deal with the inability to reset the error/trouble.

Troubleshooting (excerpt from instruction manual)
We can provide you with materials summarizing applicable troubleshooting methods from various product instruction manuals. Please feel free to contact us using the dedicated form when requesting data.

WINTECH NEO Cooling water piping cleaning method
For water-cooled models, if the cooling water piping is clogged with dust or foreign matter, abnormal pressure or abnormal temperature heating may occur. This section describes how to clean the cooling water piping.

WINTECH NEO Dust Prevention Filter Cleaning Method
For WINTECH NEO (air-cooled version), a filter cleaning alarm is triggered approximately every two months to have the dust filter inspected. This section explains how to clean the dust filter.

HIFLEX NEO-E Refrigeration Filter Cleaning Method
This section explains how to remove and clean the refrigerator filter. Please note that operation without a filter may cause dust to get into the fins of the condenser, resulting in reduced performance.

HIFLEX NEO-E Humidification Pan Cleaning Method
Long-term humidity operation can cause white solids to adhere to the humidification pan and humidification heater, which can lead to defects. This section describes the cleaning procedures and precautions needed in such cases.

HIFLEX NEO-E sub-tank cleaning method
If the operation is to be shut down for more than one month, the sub-tank must be drained. This section explains how to drain the sub-tank and the essentials of filter removal, cleaning, and reassembly.

HIFLEX NEO-E Water level adjustment method
This section explains how to check and adjust the water level in the humidification pan and wick pan. When opening the service panel during operation for adjustment, be careful to avoid electric shock, burns, or injury.

HIFLEX NEO-E Wick Gauze Exchange Instructions
Wick gauze must be replaced whenever it becomes dirty, hardened, or after operating at temperatures of 100°C or higher. This section explains how to replace wick gauze.

End of repair support
This is a guide to the end of repair support as of January 2025. This is information about the products for which continuous maintenance service cannot be provided due to difficulties in procurement of repair parts, etc.

About CFC gas (type and amount enclosed)
We provide information on the types and amounts of fluorocarbon gases used in the products handled by ETAC. If you would like to request information, please fill out the required information in the dedicated form and send it to us.

How to fill in the CFC simple inspection check sheet and record book
Under the Law for CFC Emission Control, which came into effect on April 1, 2015, equipment using CFCs is required to undergo a simple inspection at least once every three months. Please click here to see the simple inspection procedure.

Simplified Inspection" procedure in accordance with the Fluorocarbons Emission Control Law
The Fluorocarbons Emission Control Law, which came into effect on April 1, 2015, requires periodic inspections and record keeping. Here is a guide to the products subject to this law, inspection procedures, and management details.

Use of Asbestos in Our Products
We provide information on the use of asbestos in some of the products we have handled in the past. To request information, please fill out the required information in the dedicated form and send it to us.
