Environmental Testing ChamberHigh-temperature Constant Humidity Chamber

HISPEC

HISPEC is a series of high-performance high-temperature incubators offered by ETAC. The HISPEC series is suitable for a wide range of applications from research to heat treatment and drying in production lines, and is available in a diverse lineup including horizontal and vertical models. 200°C to 500°C specifications are selectable, allowing you to choose the optimum model for your application and sample characteristics. Highly accurate temperature control backed by our long-standing technology is realized with emphasis on safety and reliability.

operability

Standard specifications include 5 operation patterns

In addition to constant value operation and auto start function operation, 2-step pattern operation 1-3 are standard specifications. Each of these pattern operations can be set to repeat, and one-touch operation is all that is required for the second and subsequent operations.

  • Regular operation (auto-stop operation)Operation: Constant temperature and constant time.
  • Auto start operationAfter waiting for a certain period of time, it operates at a certain temperature and for a certain period of time.
  • Pattern 1 operation: Operates at two different temperatures and times (not including temperature change time).
  • Pattern 2 operation: Operates at two different temperatures and times (including temperature change time).
  • Pattern 3 operation (temperature gradient operation)Operation with two types of target temperatures and temperature change times.

Overshoot eliminated when temperature rises

Unique temperature control PID control system enables precise control at any temperature setting. Overshooting during temperature rise is prevented and control performance is improved.

Easy setup and operation

  • interactive interaction
    Setting items required for operation are displayed sequentially in an interactive format by pressing the menu key, and can be easily set by simply entering numerical values.
  • Intuitive Graphics
    The control panel has a setting value input section on the right, and images connected by numerical values and symbols are collectively displayed; LEDs and pull-out lines make operation easy to understand and intuitive.
  • Japanese display
    All displayed characters are in Japanese for ease of understanding.
  • simple operation
    Four basic keys can be used to make settings with a few movements. Help display and guides make the interface easy to use even for beginners.

Setting value always displayed

The set temperature and remaining operation time are always displayed, allowing the current operation status to be checked at a glance.

Lightweight operation

Recessed operation keys, menu-driven setting items, and a bright, easy-to-read digital display provide a comfortable and enhanced operating feel.

Full range of included features

It is equipped with a full range of accessory functions, including a power failure recovery protection function, heater output monitoring function, and test termination output and trouble output.

  • during a power outage: The set value and total time are backed up and not automatically restored (display alternates between the set temperature and remaining time).
  • Heater output: Digital display of heater output during operation.

safety

Abnormal judgment detection step

HISPEC monitors multiple temperature changes in the tank, and in the event of abnormal temperatures, multi-layered safety controls are activated, shutting off the heater circuit as necessary to ensure safety.

  1. A/D conversion
  2. CPU Judgment
  3. Temperature Setting Comparison
  4. Over-rise and over-low judgment
  5. Heater circuit ON/OFF control

Response to changes in tank temperature

The HISPEC series is equipped with a threefold over-temperature protection mechanism to prevent abnormal temperature rises in the tank. First, a soft-controlled over-temperature limiter is activated, and if for some reason it is not activated, a hard-controlled over-temperature limiter is activated next. If the over-temperature protection still fails to stop, a thermal fuse finally interrupts the circuit to ensure safety in a multilayered manner.

Temperature condition

safety device

operation

display

Thermal cutoff operating temperature exceeded

thermal fuse

Forced heater circuit break

nashi (Pyrus pyrifolia, esp. var. culta)

Exceeds max. specification temperature +50°C

Over-temperature protector 1 (ETACOM: Hard)

Heater circuit OFF

Abnormality lamp + Er01 light + Alarm sound

Upper setpoint temperature exceeded

Over-temperature protector 2 (ETACOM: Soft)

Heater circuit OFF

Abnormality lamp + Er02 light + Alarm sound

Exceeds temperature setting by +10°C

Built-in temperature controller (etacom)

Continuous Drive

AL1 lighting + alarm sound (intermittent sound)

Set temperature

Built-in temperature controller (etacom)

Continuous Drive

AL2 lighting + alarm sound (intermittent sound)

Lower limit set temperature

Built-in temperature controller (etacom)

Heater circuit OFF

Abnormal lamp + heater circuit OFF + alarm sound

series structure

How to read the model

S

type

Horizontal:S

Vertical:HS

Safety specification for solvent drying:HG

High temperature:EHT

/

3

Max. temperature

2: 200°C

3: 300°C

/

20

Internal dimensions: Horizontal (WxHxD mm)

10 : 450×450×450

20:600×600×600

40:800×1000×800

50: 1000 x 1000 x 800

Internal dimensions: Vertical (WxHxD mm)

40 : 600 x 900 x 600

50 : 450×450×450

60 : 450×450×450

/

sadist

type

sadistWith explosion vent

kForced exhaust type

NNon-oxidation specification

indecentHigh temperature specification

HISPEC horizontal type

The horizontal model is the standard model of the HISPEC series. It heats a large sample chamber efficiently and combines stable temperature distribution performance with ease of operation.

Highly accurate temperature distribution performance by eliminating overshoot

In addition to an in-vessel structure that takes advantage of many years of chamber technology, the use of a propeller fan with high air volume greatly improves circulation performance. Excellent temperature distribution performance of ±1.5°C (±2.0°C for #40 type and above) and high stability are realized.

Functions can be switched according to purpose

The hot air circulation function and the unidirectional hot air exhaust function can be used separately by switching the ventilation damper on the front, lower left or upper left side of the main unit. This function can be flexibly adapted according to the sample and purpose.

Simple maintenance zones

The number of parts used has been thoroughly reduced to improve reliability in long-term operation. As a result, the number of maintenance requirements has been greatly reduced, and the reliability of the entire system has been further enhanced.

Unitization of heater section realizes cost reduction

ETAC's uniquely designed heater section is commonized with other models by unitization. Cost reduction and standardization of assembly processes are realized.


HISPEC Vertical

The space-saving design of this vertical model enables processing of a large number of samples while reducing the footprint. Forced circulation by a sirocco fan provides sufficient uniform heating even when the distance between samples is relatively narrow.

Space-saving design

The main unit is vertically oriented and the exhaust port is located on the ceiling. This saves space in the installation area.

Capable of heat treating many samples at the same time

Hot air circulation is forced by a sirocco fan, which ensures sufficient circulation efficiency even when the distance between specimens is relatively small, allowing heat treatment of many specimens at the same time.

Heater unit with excellent durability

Sheathed heaters are standard equipment, enabling safe and long-term continuous use even when a large number of samples are loaded.

Dial damper knob

The damper knob is a dial type, allowing the degree of opening to be determined at a glance. It is also equipped with a lock mechanism to prevent accidental operation.

Adoption of heat-resistant decorative frames for control equipment

A heat-resistant decorative frame is used to prevent adverse effects on control equipment caused by opening and closing the door, even during high-temperature operation.

Improved safety when opening and closing doors during operation

Opening the door during high-temperature operation activates the door limit switch and stops the circulation fan, preventing workers from being blown by the hot air.


HISPEC S type with explosion vent

This high-temperature unit with explosion vent is suitable for environments where flammable gas (vapor) is generated during drying. In the event of an explosion, the pressure is safely released from the exhaust vent in the ceiling to protect workers and the surrounding environment. However, it cannot be used when large amounts of flammable vapors are generated.

Equipped with vents to exhaust wind pressure completely

A pressure-relief opening (vent) is installed in the ceiling. Venting is safe in the event of an explosion.

Safety-conscious structure

The exhaust section is securely covered to a height of 1.8 m above the floor. The door perimeter is equipped with a locking mechanism that makes it easy to open and close while maintaining sufficient strength.

Superior operability

Easy operation from temperature setting to start of operation provides an intuitive operating feel common to the series.


HISPEC K type Hot air forced exhaust type

This is a hot-air exhaust type high-temperature unit developed for heat treatment of secondary vulcanization as typified by silicone rubber. It uses a one-way complete exhaust system that efficiently discharges gases during vulcanization to the outside of the tank, thereby enhancing the safety of the work environment.

Discharge of vulcanized folded material to the outside

Fresh air induction and forced exhaust increases circulation efficiency, and treatment is performed without affecting vulcanized materials or external components.

Double swinging door for easy operation

Double-sliding structure reduces the opening radius to half. Improves productivity during high-temperature operations.

Easy-to-operate control functions

Auto start/stop/weight functions are standard, allowing easy operation with one-touch operation the next time.


HISPEC HG type High temperature tank with safety specifications for solvent drying

The HG type is a high-temperature unit with safety specifications for solvent drying, designed based on the concept that "safety takes precedence over everything else. It can safely perform heating and drying operations that involve the generation of flammable vapors, such as ceramic molding processes and drying after cleaning electronic components.

Adoption of forced exhaust system

A forced exhaust airflow system is used to blow air inside the tank. Flammable gases generated in the tank are constantly exhausted to the outside, preventing their concentration from rising.

Gas concentration alarm as standard equipment

Equipped with a high-temperature compatible gas concentration alarm to monitor the inside of the test chamber at all times. It is equipped with a safety function that enables operation only when the gas concentration is below the lower limit.

People-friendly safety design

The door structure is designed for ease of operation and safety, with a simple locking mechanism and safety interlock. Equipped with an uninterruptible power supply, the ventilation continues for a certain period of time even during a power failure.

Equipped with safety structures throughout

Various safety devices such as explosion vent mechanism are standard. Special inner tank structure design ensures high safety.


HISPEC N type Non-oxidation incubator

Heat treatment of components with copper or silver electrodes requires careful attention to the relationship between temperature and oxide film. HISPEC N type guarantees a residual oxygen concentration of 100ppm or less, realizing a heat treatment environment with minimal oxidation. It enables high-performance and low-cost non-oxidation testing, contributing to worker safety and productivity improvement.

Guaranteed residual oxygen concentration of 100ppm or less

It can stably reproduce residual oxygen concentrations of 100 ppm or less while reducing the amount of N₂ gas used to 1/5 of the conventional level.

Improved temperature lowering mechanism

Ability to lower temperature from 250°C with the door closed is 1.5 times faster than conventional units. Expands the workable area. If further shortening is required, a water cooling mechanism (optional) is available.

Temperature uniformity

Temperature distribution performance of ±3.5°C (at 250°C setting) is guaranteed. Improves heat treatment yield.


HISPEC H type High-temperature unit

This model is suitable for heat resistance tests and high temperature life tests of inorganic materials such as ceramics and various metals, and engineering plastics at MAX500℃. It can be operated safely and precisely even in high temperature ranges.

High performance and high precision

Reaches MAX500°C in about 60 to 70 minutes. Unique PID control suppresses overshoot and provides excellent temperature distribution inside the tank.

Designed with safety in mind

Triple safety mechanism against abnormal temperatures (over-temperature limiter, upper limit setting, and thermal fuse). Door lock mechanism and highly sealed structure with double packing for long time use.

Easy-to-use controller

The HT/HS series shares the same operation system with the HT/HS series, with 2-step programmed operation, auto-start/auto-stop, and each safety device operation display as standard features. Intuitive operation.


option

A wide range of options to enable optimal specifications according to the purpose of use.

Over-temperature protector (temperature control type)

Used when quadruple safety or heater room temperature control is required in addition to the standard safety mechanism.

sheath heater

SUS304 for horizontal type, reinforced corrosion resistance and red-hot prevention, standard for HS/S/HG/N types.

Variable wind speed mechanism

Fan speed can be adjusted for testing under low air velocity conditions such as film drying.

Automatic damper

Automatic control of damper opening in conjunction with test end output, trouble output, and time signal.

Exhaust Duct

Effective for outdoor exhaust when rear exhaust is to be avoided. Optimizes the exhaust route to suit the environment and the line of flow.

Simple N₂ displacement mechanism

For treatment of specimens that do not tolerate oxidation. Simplified non-oxidizing atmosphere.

External alarm terminal / Test end terminal

Outputs abnormalities and termination to external equipment (standard for N and HG types). Contact rating of the test termination terminal is AC250V 3A.

buzzer switch

Audible notification of the end of the test or the occurrence of a problem.

rotation warning light

Linked to trouble output and visualizes abnormalities with a rotating flash (models with buzzer available).

emergency stop switch

In the event of an emergency, the breaker interrupts the current and immediately stops operation.

calendar timer

AM/PM for weekly automatic operation schedule.

paperless recorder

Can be saved to CF card and imported to PC with included software. Compatible with percussion recorder.

Observation window (with in-tank light)

Made of heat-resistant tempered glass; meets 200°C specifications and improves visibility during operation.

integration timer

The time used can be totaled and utilized for maintenance planning and operation analysis.

Trestle (assembled type)/Angle type trestle

Adjustable height for easy work. Angle type is equipped with casters for easy carrying in and installation.

Shelf / Load-bearing shelf board

Standard 15 kg and load capacity 50 kg (equally distributed). Shelf pitch is 50mm for flexible adjustment.

Racks & Rack Carts

Production transport fixture. Racks and carts are wheeled for ease of operation.

Measuring port (φ25/φ50/φ100)

Measurement port used to take out lead wires and sensors.

RS485 Interface

Supports remote monitoring and data collection via external communication (9600 bps/half-duplex/8N1).

Double swinging door (for horizontal type)

Reduced door turning radius saves space and improves workability for loading and unloading.

Recorder output terminal

K thermocouple signals can be output to an external recorder.

Casters & Adjusters

Integrated legs for both movement and leveling, standard on HS/N types.

Automatic Power-Outage Recovery Function

Automatically resumes operation after power failure. Supports unlimited time restoration.

Remote Functions

Operation start/stop can be remotely controlled by an external signal (remote terminal on rear panel).

Voltage application terminal

Voltage can be applied to the test object under test in high temperature operation tests, load life tests, etc.

time signal

Two contact points are activated at any step of pattern operation (AC250V 3A).

Program specifications (max. 20 steps)

Supports programmed operation of up to 20 steps x 3 patterns (N type standard).

weight function

Excluding the temperature rise time, only the maintenance time is counted (valid for constant value operation/standard for K type).

2-step metal fittings

Special fittings for loading horizontal type in two levels, top and bottom.

Floor load-bearing reinforcement

The tank floor is reinforced to support heat treatment of heavy materials.

Gear aging mechanism

This is a dedicated mechanism that is individually designed for each application.

Body paint color Specified