Basic performance
- number of steps:2
- Inside dimensions600 x H600 x D500 mm x 2
- content by volume180 L × 2
- Temperature range:30°C to +100°C (+150°C and -40°C are available as options)
Product Features
Safety
Safety mechanisms for emergencies, such as an automatic fire extinguishing mechanism and door reinforcing mechanism, are standard.
Low GWP support
Equipped with R-448A (GWP1387), which far exceeds the GWP target value of 1500 under the CFC Emission Control Law. Compared to the conventional refrigerant R-404A, R-448A reduces environmental impact by 65% and avoids the concern of reduced refrigerant supply after the regulation.
Various options
An optimal test environment can be constructed with a variety of options to meet the required safety level, usage environment, and test objectives.
Large capacity 180 liters
The test chamber has a large capacity in spite of its space-saving design. It can be used according to sample size and purpose, contributing to efficiency and energy savings.
Space-saving design
The multi-level stacking concept carved out by ETAC saves space. Compact design with two-tiered stacking of test chambers.
operability
Door reinforcing mechanism
Reliable tightening handles and reinforced hinges ensure strong safety of the door section.
Sheath heater specifications
Heating method suitable for rechargeable battery evaluation with long life, excellent safety, and resistance to oxidation and corrosion.
Automatic fire extinguisher
Each tank is equipped with a CO2 fire extinguisher as standard. In the event of an emergency, the fire extinguisher is activated by an independent power supply to ensure fire extinguishing.
emergency stop switch
Located on the front of the device to ensure ease of operation in an emergency.
Ethernet
Interface to work with charging and discharging systems.
Door limit switch
Interlock function enables safety linkage with fire extinguishing mechanisms and charging/discharging systems.
Multilayer over-temperature protection device
Triple configuration of hydraulic expansion thermostat, temperature sensor, and controller settings monitors abnormal temperatures.
Observation window with cover
Enables wide-field observation of the EUT in the chamber while ensuring safety.
120mm dia. measurement hole
One on each side of each tank (two in total) for greater flexibility in system connections.
External output signal
Outputs signals to external parties in the event of trouble.
external input signal
Control signals from the charge/discharge system can be used to stop the thermostatic chamber, etc.
option
Additional Φ120mm measurement hole
Can be expanded up to 6 units.
smoke detector
Smoke from the EUT is detected and linked to trouble stoppage and fire extinguisher activation.
Signal Tower
Notification of event occurrence by lighting color.
Floor Fixture
Fixed to the floor with anchor bolts.
-40°C specification
The lower temperature limit is extended to -40°C.
+150°C specification
Expanded temperature limit to +150°C (possible up to +180°C with special handling).
Non-frost specification
Prevents frosting of refrigeration equipment during long-term operation at +10°C to +35°C.