Basic performance
- number of steps1-3
- Inside dimensionsW500 x H350 x D350 x 1-3, W600 x H600 x D500 x 2
- content by volume61L x 1-3 / 180L x 2
- Temperature range:: -40°C to +100°C
- Humidity rangeThe following table shows the list of the standard products for the following models: 20%RH to 98%RH.
Product Features
High temperature and humidity characteristics
Shares components with the high-end HIFLEX NEO-E model to achieve stable temperature and humidity characteristics. Capable of humidification operation up to 98%RH, it can handle a wide range of testing conditions.
Powerful sirocco fan
A sirocco fan with large air volume and high air pressure is employed. Even with specimens installed, uniform distribution performance within the chamber is ensured.
DC inverter controlled air-cooled rotary chiller
Equipped with DC inverter controlled air-cooled rotary chiller. Refrigeration system efficiency
Optimized refrigeration capacity by unique refrigerant flow control using an electronic expansion valve. Guaranteed temperatures up to -40°C. The test environment is stabilized and power consumption is drastically reduced.
Ambient operating temperature
It retains robustness to reach the minimum temperature (-40°C) even when the ambient temperature is +35°C.
Humidified water sterilizer (optional)
UV irradiation sterilization lamps are used to inhibit the growth of bacteria, preventing problems caused by sliminess and water stains in the piping system. This improves the reliability of water circuits.
operability
- Rectangular cable holes (both sides)Standard: Rectangular cable holes are provided on both sides of the main body. Measurement devices can be installed on either the left or right side. This greatly expands the degree of freedom of installation location.
- Water AttachmentWater supply tank with a capacity of 10 liters can be easily removed with a one-touch operation for easy water supply and cleaning.
- Dust filterHigh maintainability is also taken into consideration for the dust filter of the condenser for refrigeration equipment. Periodic cleaning can be easily performed.
- Main unit control panelSimple program setting is possible with simple operation.
- PC/Tablet connection: Advanced management such as operational settings, status monitoring, data downloading, and e-mail notifications can be performed via a Web browser.
- Smart Connect (optional)Intuitive touch panel operation enables detailed settings and data management.
Environmentally Friendly
Low GWP refrigerant R-448A is used
With a GWP value of 1387, it reduces environmental impact by approximately 65% compared to conventional R-404A. With an ozone depletion potential (ODP) of zero, it is a nonflammable, nontoxic, and inert refrigerant. It meets the 2025 target value (GWP of 1500 or less) under the CFC Emission Control Law.
Low Temperature Incubator
HIFLEX NEO-ES FL type
Basic performance
- number of steps1-3
- Inside dimensionsW500 x H350 x D350 x 1-3, W600 x H600 x D500 x 2
- content by volume61L x 1-3 / 180L x 2
- Temperature range:: -40°C to +100°C
option
+150°C specification
+180°C specification
water purifier
Power cable (8m)
Power cable (3m)
Main body fixing metal fittings
Additional cable hole (round φ50)
Additional cable hole (square)
Additional cable hole (round φ120)
inspection report
Certificate of Calibration
SUS cooling coil specifications
Polymer sensor type hygrometer
Low siloxane gas specification
Automatic Power-Outage Recovery Function
Shelf board and shelf support (load capacity: 15 kg)
Signal Tower
rotation warning light
Additional over-temperature protector
emergency stop switch
defrosting device
non-frosting device
Arm-type terminal fixing stand
Smart Connect (dedicated terminal)
paperless recorder
RS485 interface
integrated timer with reset
Weipalace Observation Window
Tempered glass inner door
Butt for chamber body
Smart Controller (web substrate)
Shelf board and shelf support (load capacity: 30 kg)
Power cable (5m)
specification sheet
model (e.g. of a vehicle) | SXN401-E | SXN402-E | SXN403-E | SXN412-E | SLN401-E | SLN402-E | SLN403-E | SLN412-E |
Temperature range | -40°C to +100°C | |||||||
Humidity range | 20%RH to 98%RH | – | ||||||
Temperature rise time | Within 35 minutes -40°C to +100°C | |||||||
Temperature fall time | Within 55 minutes +20°C to -40°C | Within 50 minutes +20°C to -40°C | Within 55 minutes +20°C to -40°C | Within 50 minutes +20°C to -40°C | ||||
Temperature change rate (rise) | 4.0°C/min -26°C to +86°C | |||||||
Temperature change rate (descending) | 2.5°C/min +86°C to -26°C | 3.0°C/min +86°C to -26°C | 2.5°C/min +86°C to -26°C | 3.0°C/min +86°C to -26°C | ||||
Temperature and humidity fluctuations | ±0.3°C/±2.5%RH | ±0.3°C | ||||||
Temperature and humidity gradient | 3.0℃ in temperature operation|2.0℃/5.0%RH in temperature/humidity operation | During temperature operation 3.0°C | ||||||
Space temperature and humidity deviation | 2.5℃ during temperature operation|1.5℃/5.0%RH during temperature/humidity operation | During temperature operation 2.5°C | ||||||
Operable ambient temperature range | +5°C to +40°C | |||||||
Internal dimensions (W x H x D mm) | 500 x 350 x 350 | (500 x 350 x 350) x 2 | (500×350×350)×3 | (600 x 600 x 500) x 2 | 500 x 350 x 350 | (500 x 350 x 350) x 2 | (500×350×350)×3 | (600 x 600 x 500) x 2 |
Content (liter) | 61 | 61 x 2 | 61 x 3 | 180 x 2 | 61 | 61 x 2 | 61 x 3 | 180 x 2 |
External dimensions (W x H x D mm) | 660 x 1285 x 1040 | 660 x 1885 x 1040 | 660 x 1955 x 1375 | 760 x 1855 x 1645 | 660 x 1285 x 1040 | 660 x 1885 x 1040 | 660 x 1955 x 1375 | 760 x 1855 x 1645 |
Mass (kg) | 190 | 330 | 500 | 475 | 185 | 325 | 495 | 470 |
Exterior Steel Plates | bonder steel sheet (Baked finish) | |||||||
Inner tank steel plate | Stainless steel plate (SUS304) | |||||||
ventilator | sirocco fan | |||||||
refrigerator | DC inverter controlled air-cooled rotary chiller | |||||||
refrigerant | R-448A | |||||||
Heating Heater | Nichrome Strip Heaters | |||||||
humidifier | sheathed heater (SUS316L) | – | ||||||
cooler | Plate Fin Coil | |||||||
Control Sensors | JIS C1604 3-wire resistance thermometer Pt100 | |||||||
Control method | PID control | |||||||
Display method | LED indication | |||||||
Display resolution | 0.1°C/1%rh | 0.1°C | ||||||
Setting method | Key-in method using the main unit’s display unit / input method using Smart Connect (optional) or a terminal equipped with a Web browser | |||||||
Ethernet | 10BASE-T/100BASE-TX AUTO-MDIX compliant RJ45 connector x 1 channel | |||||||
USB | USB2.0 TYPE A connector x 1 channel | |||||||
memory capacity | 8GB | |||||||
power (button on TV, etc.) | AC200V 3φ 50/60Hz Voltage fluctuation range ±10% Class D grounding | |||||||
humidified water | Ion-exchanged water or pure water, etc. (0.1 to 10 μS/cm) | – | ||||||
Maximum load current (A) | 15 | 30 | 45 | 46 | 9 | 18 | 27 | 32 |
Operating current (A) | 11 | 22 | 33 | 34 | 7 | 14 | 21 | 26 |
Exhaust heat (kW) | 0.62 to 3.6 | 1.24-7.2 | 1.86-10.8 | 1.0-9.6 | 0.62 to 3.6 | 1.24-7.2 | 1.86-10.8 | 1.0-9.6 |
safeguard | Main power leakage circuit breaker, fan motor overload relay, temperature overload protection device, refrigerator pressure switch, refrigerator overload relay, refrigerator overheat protection device, reverse phase detector, heating heater overload protection fuse, control circuit overload protection fuse, sensor disconnection detection function, temperature (humidity) upper/lower limit alarm function, power failure notification alarm, Filter cleaning alarm, Empty heating preventer, Humidifier heater overload protection fuse, Wick drying alarm, Water supply tank water level low alarm, Circuit protection ground-fault circuit breaker, Inverter abnormality detection function | Main power leakage circuit breaker, fan motor overload relay, over-temperature protection device, refrigerator pressure switch, refrigerator overload relay, refrigerator overheat protection device, reverse phase detector, heating heater overload protection fuse, control circuit overload protection fuse, sensor disconnection detection function, upper and lower temperature limit alarm function, power failure notification alarm, filter cleaning alarm, circuit protection earth leakage circuit breaker, inverter error detection function | ||||||
Ancillary Functions | Memory backup function, pause function, monitor function, self-diagnostic function, power failure return protection function, instantaneous power failure retention function, external alarm output function, test termination output function, EUT power supply interlock function, auto-start/timer function, humidification delay function, standby operation function at room temperature | Memory backup function, pause function, monitor function, self-diagnostic function, power failure return protection function, instantaneous power failure retention function, external alarm output function, test termination output function, EUT power supply interlock function, auto-start/timer function, standby operation function at room temperature | ||||||
body (of a machine) | Square measurement hole (100 x 30 mm, 2 locations on left and right sides), caster adjuster, dust filter for refrigerator condenser | Square measurement hole (100 x 30 mm, 2 locations on left and right sides), caster adjuster, dust filter for refrigerator condenser | ||||||
accessory | Wick gauze (12 wicks/tank), silicon stopper for square measurement hole (2 stoppers/tank), adjuster fixture (4 fixtures/unit, depending on model), key for door latch (2 keys/tank), instruction manual (1 copy), water tank (401, 402: 10L, 403, 412: 20L, all models 1 tank/unit), certificate of inspection acceptance | Silicone plugs for square measurement holes (2/tank), adjuster fixture (4/unit, depending on model), keys for door latches (2/tank), instruction manual (1 copy), inspection certificate | ||||||