WeissTechnikindicates word or phrase being defined
Weiss Technik is the world's leading manufacturer of environmental test equipment, deploying a diverse range of equipment for climatic testing, thermal shock testing, and vibration testing. Based in Germany, the company has earned a global reputation for its technologies that support quality assurance and R&D. The company has also strengthened its commitment to sustainability and energy conservation, actively adopting the latest refrigerant technologies and efficient control systems.
Basic performance
- Temperature range:: -80°C to +220°C
- Test area travel timeWithin 10 seconds
- Maximum load capacityMaximum weight: 100 kg (T/300 model)
- Return Time to TemperatureWithin 12-15 minutes (under standard conditions)
- High airtightness and corrosion resistanceStainless steel test chambers are used
Product Features
Sample transfer type structure
By switching between high and low temperature chambers in a short period of time, specimens are subjected to instantaneous temperature changes to realize highly reproducible cold thermal shock testing.
Defrost-free operation
The unique mechanism enables continuous operation of more than 1,000 cycles, eliminating the need for test interruption due to defrosting.
Independent use of high and low temperature tanks
Each chamber can be used as an independent chamber and can be utilized not only for thermal shock testing but also for independent high or low temperature testing.
Robust construction
The test chamber is made of highly corrosion-resistant stainless steel to maintain stable performance even with rapid temperature changes and long-term operation. Product Features
operability
- Large observation windowWidth: 355 mm x Height: 355 mm. all models are equipped as standard for high visibility.
- Sample basket with meshSafety is improved by preventing specimens from falling.
- access portReduces the load on the cable and maintains measurement accuracy.
- 7-inch color TFT touch panelIntuitive operation screen with full Japanese support.
- WEBSeason®.Remote access from smartphones and tablets, with chart preview function.
- S!MPATI®.: Up to 99 test instruments can be centrally managed, and data can be documented and edited (optional).
- CSV output: Test results can be saved on a USB memory stick and analyzed with common spreadsheet software.
Environmentally Friendly
- Adoption of low GWP refrigerant R449AGlobal warming potential is reduced to about 1/3 that of conventional refrigerants.
- Compliance with European F-Gas Regulations: Can be used safely even after 2030
- economical modeEnergy savings of up to 37% is achieved by controlling the unused tanks without heating or cooling them.
- CO2 emission reductionContributing to sustainability by reducing environmental impact
(product) line-up
ShockEvent offers five basic models, which can be selected according to sample size and test purpose.
specification sheet
model (e.g. of a vehicle) | T/60/V2 | T/120/V2 | T/120/V2/P | T/300/V2 | T/300/V2/P |
system | Two-zone method with vertical sample movement | ||||
High temperature exposure temperature range | +50°C to +220°C | ||||
Low temperature exposure range | -80°C to +70°C | ||||
Temperature fluctuation | ±0.3K to ±1.0K | ±1.0K | |||
Space temperature deviation | ±0.5K to ±2.0K | ±2.0K | |||
Preheat upper limit temperature | +220°C | ||||
Temperature rise time | Approx. 10 min. From +50°C to +200°C | Approx. 12 min. From +50°C to +200°C | Approx. 7 min. From +50°C to +200°C | Approx. 14 min. From +50°C to +200°C | Approx. 8 min. From +50°C to +200°C |
Temperature change rate (rise) | 17K/min | 14K/min | 18K/min | 11K/min | 23K/min |
Lower limit of pre-cooling temperature | -80°C | ||||
Temperature fall time | Approx. 70 min. +70°C to -80°C | Approx. 41 min. +70°C to -80°C | Approx. 33 min. +70°C to -80°C | Approx. 45 min. +70°C to -80°C | Approx. 26 min. +70°C to -80°C |
Temperature change rate (descending) | 3.7K/min | 6.3K/min | 7.5K/min | 5.0K/min | 12K/min |
Temperature change rate (rise) | 3.2K/min | 2.0K/min | 2.0K/min | 1.5K/min | 1.5K/min |
return condition | MIL-STD-883K 1010.9 Level D: IC4.5kg | MIL-STD-883K 1010.9 Level D: IC12kg | MIL-STD-883K 1010.9 Level D: IC20kg | MIL-STD-883K 1010.9 Level F: IC25kg | MIL-STD-883J 1010.9 Level F: IC50kg |
return time | <15 min. <15 min. | <12 min. | <15 min. | ||
Test area travel time | <10 sec. | ||||
Allowable heat generation load | Max. approx. 2.0 kW (-50°C to 0°C) | Max. approx. 6.0 kW (-50°C to 0°C) | Max. approx. 8.0 kW (-50°C to 0°C) | ||
Operable ambient temperature range/relative humidity | +10 to +35°C/75%RH or less | ||||
External dimensions (W x H x D mm) | 900 x 2330 x 2150 | 1000 x 2450 x 2530 | 1000×2450×2805 | 1320 x 2900 x 2370 | 1320 x 2900 x 2370 |
External dimensions of separately installed chiller unit (W x H x D mm) | – | 800 x 1950 x 2100 | 1000 x 2080 x 2400 | ||
Minimum external dimensions when carried in (W x H x D mm) | 900 x 1895 x 2220 | 1000 x 1985 x 2600 | 1000 x 1985 x 2875 | 1350 x 2250 x 2340 | 1350 x 2250 x 2340 |
Minimum external dimensions (W x H x D mm) when separately installed chiller unit is carried in | – | 800 x 1920 x 1920 | 1000 x 2050 x 2330 | ||
Mass (kg) | Approximately 800 | Approx. 1000 | Approx. 1200 | Approx. 1630 (950+680) | Approx. 1950(1100+850) |
Test area dimensions (W x H x D mm) | 380 x 370 x 430 | 470 x 410 x 650 | 770 x 610 x 650 | ||
Test area volume (liter) | 60 | 120 | 300 | ||
Max. number of shelves | four flat objects (e.g. tickets, pieces of cloth, etc.) | five flat objects (e.g. tickets, pieces of cloth, etc.) | eight flat objects (e.g. tickets, pieces of cloth, etc.) | ||
Test area load capacity (kg) | 20 | 50 | 100 | ||
door | With observation window, door handle (right handle, left hinge, with key) | ||||
Window size (W x H mm) | 355 x 355 | ||||
Sample basket load capacity (per sample basket) | 2.5kg | 4.0kg | |||
access port | φ80(ceiling) | ||||
refrigerator | Air-cooled, low-noise, 2-way refrigeration system | Water-cooled, low-noise, dual-refrigeration system, 2-way cooling water control | |||
Refrigerant used | R449A+R23 | ||||
cooler | Plate Fin Coil | ||||
High/low temperature chamber thermal fuse | 1 each of high and low greenhouse | ||||
Control method | PID control | ||||
Setting/Indicator | Attached to door | ||||
Display method | 7-inch LCD | ||||
Setting method | Interactive method with LCD touch panel | ||||
Upper and lower limit temperature settings | Temperature can be set for both high and low temperature rooms | ||||
Ethernet | 1 pcs (100/1000MB) | ||||
USB | 1 piece | ||||
Digital IO (dedicated connector) | Input 4 pcs (24V DC, 30mA) / Output 4 pcs (24V DC, ~0.5A) | ||||
Protection TYPE | IP54 | ||||
Power supply (with transformer) | AC200V 3φ 50/60Hz Voltage fluctuation ±10% | ||||
Water temperature 18°C, inlet/outlet temperature difference 10 K (K/minute) (When MIL-STD 833G is implemented) | – | 22 | 44 | 117 | |
Water temperature 28°C, inlet/outlet temperature difference 5 K (K/minute) (When MIL-STD 833G is implemented) | – | 44 | 87 | 234 | |
Cooling water pressure | – | 0.25 to 0.6 MPa, inlet/outlet differential pressure 0.2 MPa or higher | |||
Cooling water temperature | – | +12°C to +28°C | |||
Cooling water connection Inlet/outlet pipe diameter | – | Inlet Rp3/4″|Outlet Rp3/4″(female thread) | Inlet Rp 1″|Outlet Rp 1″ (female thread) | ||
drain hose | 1/2″ (ø12) hose connection | ||||
Maximum load current with transformer 50/60Hz (A) | 50/55 | 100/110 | 230/254 | ||
Maximum heat removal (kW) | 7.7 | 0.8 | 2 | 3 | |
noise figure | 58dB(A) | 56dB(A) | 69dB(A) | 58dB(A) | 72dB(A) |
safeguard | Fan motor overload protection device for low-temperature chamber/high greenhouse, spindle motor overload protection device, over-temperature/over-cooling protector for sample protection, over-temperature protector for low-temperature chamber/high greenhouse for equipment protection, protective net for sample drop prevention, interlock terminal for sample energization, refrigerator pressure switch, refrigerator overheat protector, reverse phase protector for power supply, door lock mechanism, self-diagnostic function, etc. | ||||
Standard equipment (main unit/accessories) | Main unit: RJ45 connector for Ethernet, USB connector, digital I/O (4 points each, dedicated connector), over-temperature protector for sample protection, observation window (effective dimensions: W355 x H355), high temperature chamber lighting, access port (top surface: φ80, 1 piece), signal lamp, etc. Accessories: Operation manual, sample basket (1 piece), stopper for access port (1 piece), inspection report (1 set each) Access port stopper (1 pc), Inspection report (1 set each) | ||||
Supported options | Additional access ports, specimen baskets, shelves, LN2 auxiliary cooling system, additional safety devices, dehumidifier, specimen temperature sensor, temperature output mechanism, air-cooled condenser, water-cooled condenser, etc. | ||||